8XA Stanley Meyer

Hydogen Hot Rod
Page as a Pdf.png
Stanley A Meyer 8XA Alternator

Th 8XA PWM Cicuit is what Stanley Invented after trying the 10XA Variac /alternator only version , The 8XA has a seperate voltage control board calleed the 9XD. 

The 8XA is Very Close to the same as the 9XB which has the 9XD on the same board as the 8XA+9XD.

 

Latter with the 9XA and VIC the Voltage Board was seperated again to give more controls and easy maintenance.

We have seperated each page for the 8XA and 9XB ,they do cross over a little we are tuning the pages slowly, enjoy your study.

Stanley A Meyer 8xa hho Cell hydrogen

8XA Basics

Stanley A Meyer EBasic Gated Mains 8XA

Stan Meyer's 8XA circuit has one serious drawback

- if the network frequency (110 Volts / 60 Hz) will change,

"Step Charge" settings are also  changing.

As you know, the network frequency will vary!

 

For High Efficient Electrolysis, Stan Meyer use three basic principle:

 

1. "Beat Frequencies" for creating "Step charge effect"

2. "Gated signal" for Decreasing current leak, but keep voltage between the Cell electrodes !!!!!

3. Two or more serial connected Water Fuel Cells - "Еxcitor Array" for Decreasing current leak.

 

If you use 25.1 Hz, effects is produced both !

(Supply frequency 50 Hz / 220 Volts, after 4-diode rectifier 100 Hz)

 

Stan Meyer's Patent 4.798.661:

The pulsed d.c. voltage, the duty cycle pulses, the resistor from negative to ground, the serial connections of the exciters, and the plate resistor in series with a variable resistor between the negative plate and ground, is a sequence of circuits that conteract the electron leakage with increased voltage.

 

Similarly, the same sequence individually and in combination are equally applicable with respect to the variation of plate spacing to vary the rate of generation of the gasses but yet, to restrict electron leakage.

 

The voltage levels from 0 volts upward will be dependent on the physical parameters of the apparatus. In one typical structure of the apparatus the voltage was varied from zero (0) volts to 45 volts.

 

In a smaller structure, the voltage levels of FIG. 8 were utilized.

Stanley A Meyer EBasic Gated Mains 8XA
Stanley A Meyer EBasic Gated Mains 8XA

High Voltage, Low Current - Water Conductivity

 

•30 Jul 2016

 

8XA-Car Alternator.JPG

 heating estimate for 8Xa and Variable Plate Cell

 

not using gate

Calculate Water volume (4 in inside diameter)
4”dia, plate height plus 4” water over plates
V=PI()* radius^2*height = 201 cu in

Calculate plate volume (1/4 in plate backer)
V=height*width*thickness*2
V=3*12*(1/4)*2 = 18 cu in

Water volume = total volume – plate volume
Water volume = 201 – 18 = 183 cu in

Calculate lbs of water
1 gal water = 231 cu in, and 1 gal water = 8.35 lbs
Water volume = 183 / 231 = .79 gals
Water weight = .79 * 8.35 = 6.6 lbs of water in container

Calculate how much power goes toward heating the water in the container
Total input power 80V@ 4A = 320W
48700cc/hr  =  48.7L/hr = 0.8117L/min
Watts to make gas  = .8117(L/min) * 140 (W/L/min) = 113.6W
Calculate watts to heat water = Total input power – power to make gas
Watts to heat water = 320 – 113.6 = 206.4W

Calculate water temperature rise in 20 minute run
206.4W = 11.748BTU/min
BTUs in 20min = 11.748 * 20 = 235BTUs
1BTU = raise 1lb water 1degF
Water temperature rise in 20 minutes  =  235 / 6.6 = 35.6degF

If the temperature of the water started at 70degF and ran for 20 minutes then the ending cell temperature should have been at 105.6degF.

 

TDS&EC Electrical conductivity meter:

http://www.aliexpress.com/item/TDS-Te...

Electrical conductivity conversion calculator: http://www.lenntech.com/calculators/c...

 

Distilled Water – 2,2 μS/cm Double-Distilled Water – 1,6 μS/cm Forum: http://www.energy-shiftingparadigms.c...

 

Videos: Stanley Meyer’s Variable Spacing Demo Cell: https://www.youtube.com/watch?v=G-LH3...

 

Stanley Meyer's Water car - first run:

https://www.youtube.com/watch?v=Z5afw...

 

Stan Meyers Water Powered Buggy – TV Report: https://www.youtube.com/watch?v=a74ua...

 

My circuit diagram:

https://drive.google.com/open?id=0Bxn...

 

My Home-Made Water Distiller:

https://www.youtube.com/watch?v=TPkt2...

Hydogen Hot Rod

EPP Electrical Polarization Process - Bench top Unit

The 8xa is a square wave pulse with a 50% duty cycle, the 120 hz rectified house power is gated with the 8xa.

================================================================ 

you will notice there are several ways to run or make the switch to avoid amp draw . mosfet, or solid state or altnerators digital switch or scr.  we show some on this pages based on meyer original works and successful replications by leading builders. NO electrolyte So not electrolysis use double distilled water for most power fuel water fuel making

 

For more information, look my previous Video:

https://www.youtube.com/watch?v=42ygE...

 

Tap water, without electrolyte "Non-Regulated"

 

12 Volts Car Alternator Pulce Frequency to the Cell - 943 Hz "Gate" Frequency -

2 Hz Voltage to the Cell - 148 Volts Car Alternator's RPM - 10000 min-1 My circuit diagram: https://drive.google.com/open?id=0Bxn...

 

Dave Lawton's replication circuit: https://drive.google.com/open?id=0Bxn...

 

Stanley Meyer's 8XA working Circuit diagram: https://drive.google.com/open?id=0Bxn...

 

Stanley Meyer's Patent US4798661A: http://www.google.com/patents/US4798661

 

"The output voltages from the secondary windings 46 is relatively high and is in the order of two hundred (200) volts".

 

n this this following video, I was testing a 24V stator and comparing it to the stock 12V stator.

The coils are wound the normal 3 phase "WYE" style. The alternator is also deregulated.

 

The pulley's are 6" and 2". Motor speed is marked as 1725rpm. Measured frequency to the cell is 3.03Khz. Input frequency to the alternator is 120Hz.

 

There is no resonance of any kind with this design. Although, the input power is amazingly very low for this much gas

Stanley Meyers 8XA - Amazing Step Charge

Stan Meyer's 8XA circuit has one serious drawback - if network frequency (110 Volts / 60 Hz) is change, "Step Charge" settings too changing.

 

As you know, the network frequency is vary! Stan Meyer's 8XA circuit without 4-Diode Bridge Rectifier. The circuit work like Stan Meyer's VIC - "Half-wave rectification":

http://en.wikipedia.org/wiki/Rectifier

 

"Gated" Generator is tuned to 51 Hz ! (Supply frequency 50 Hz / 220 Volts) My modifying 8XA circuit with Half-wave rectification and 180 degree control:

 (Zener Diode is added)

Hydogen Hot Rod
#8xa #stanmeyer #stanleymeyer stan meyer stanley #hho hho #hydrogen #plans #design #instructions
Hydrogn hot rod
Stanley Meyers 8XA  ROTORY VOLTAGE INENSIFIER CIRCUIT
Stanley A Meyer 8XA Voltrolysis
Hydrogen Hot Rod
8XA Voltage Intensifier Circuit
Hydrogen Hot Rod
8XA Voltage Intensifier Circuit
Hydrogen Hot Rod
Stanley A Meyer Solid State Relay
Stanley A Meyer Solid State Relay
Stanley A Meyer Solid State Relay
Stanley A Meyer Solid State Relay

In this Case we can use dc to dc solid state switch or dc to ac as we conneect to rectifier , heat is a luxury stan didn't have same

Hydrogen Hot Rod

or more information, look my previous Video:
https://www.youtube.com/watch?v=42ygEyRW4PQ

 


Tap water, without electrolyte
"Non-Regulated" 12 Volts Car Alternator
Pulce Frequency to the Cell - 943 Hz
"Gate" Frequency - 2 Hz
Voltage to the Cell - 148 Volts
Car Alternator's RPM - 10000 min-1

My circuit diagram:
http://alfa.kachi-snimka.info/images-2013/viu1467775093e.JPG

Dave Lawton's replication circuit:
http://alfa.kachi-snimka.info/images-2013/viu1468991760r.jpg

Stanley Meyer's 8XA working Circuit diagram:
http://alfa.kachi-snimka.info/images-2013/jdv1468769704m.jpg

Stanley Meyer's Patent US4798661A:
http://www.google.com/patents/US4798661
"The output voltages from the secondary windings 46 is relatively high and is in the order of two hundred (200) volts".

8XA Voltage Intensifier Circuit

Can the Supply voltage variations to Variac effect the out come? YES

Stan Meyer's 8XA circuit has one serious drawback - if network frequency (110 Volts / 60 Hz) is change, "Step Charge" settings too changing. As you know, the network frequency is vary!

For High Efficient Electrolysis, Stan Meyer use three basic principle:
1. "Beat Frequencies" for creating "Step charge effect"
2. "Gated signal" for Decreasing current leak, but keep voltage between the Cell electrodes !!!!!
3. Two or more serial connected Water Fuel Cells - "Еxcitor Array" for Decreasing current leak.

If use 25.1 Hz, effects is produced both !
(Supply frequency 50 Hz / 220 Volts, after 4-diode rectifier 100 Hz)

Stan Meyer's Patent 4.798.661:
The pulsed d.c. voltage, the duty cycle pul